  * IBM ServeRAID Command Line Programs                              *
  * Version 3.50                                                     *
  * ******************************************************************

  This README file contains instructions for installing and starting
  the IBM ServeRAID IPSSEND and IPSMON command-line interface
  programs.

  IPSSEND and IPSMON are advanced command-line programs that you can
  use to manage your ServeRAID adapters and controllers.  These
  utility programs are provided on the IBM ServeRAID Command Line
  Programs Diskette.

     **** Important Information ****

     This diskette is a DOS bootable diskette; the user can use the
     DOS version of the IPSSEND program after booting.

     NOTE:
     See the README file on the "IBM ServeRAID BIOS/Firmware Update
     Diskette" for descriptions of the current ServeRAID diskettes
     and for detailed information about the changes and enhancements
     provided with each version.

  For more information about IBM ServeRAID and server products, visit
  http://www.pc.ibm.com/support


  _____________________________________________________________________
  CONTENTS
  ________

  1.0  About the IPSSEND and IPSMON Programs
  2.0  Installing IPSSEND and IPSMON
  ... 2.10  Installing IPSSEND and IPSMON for OS/2, Windows NT, or
            Netware
  ... 2.20  Installing IPSSEND and IPSMON for SCO OpenServer
  ... 2.30  Installing IPSSEND and IPSMON for SCO UnixWare
  3.0  Instructions for Starting IPSSEND and IPSMON
  ... 3.10  Starting the IPSSEND Program
  ... 3.20  Using the IPSSEND Program
  ... 3.30  Starting the IPSMON Program
  ... 3.40  Using the IPSMON Program
  4.0  Using IPSSEND and IPSMON
  5.0  Trademarks and Notices


  ____________________________________________________________________
  1.0  About the IPSSEND and IPSMON Programs
  __________________________________________

  You can use the IPSSEND program to view the configuration of a
  ServeRAID adapter or controller, rebuild a defunct drive, initialize
  logical drives, synchronize logical drives, and perform other
  functions.

  You can use the IPSMON program to monitor a ServeRAID adapter or
  controller for defunct drives, predictive failure analysis (PFA)
  warnings, rebuild operations, synchronizations, and logical-drive
  migrations.  This program can log a message to the monitor, to a
  file, or to both the monitor and a file whenever activities occur.

  You can use the IPSSEND and IPSMON programs with the following
  operating systems:

  o   IBM OS/2 Warp Server and OS/2 LAN Server
  o   Novell NetWare 3.12, 4.1X, and 5.0
  o   Microsoft Windows NT
  o   SCO OpenServer 5.0.X
  o   SCO UnixWare 7.0

  You also can use the IPSSEND program with DOS, but DOS requires the
  ASPI Manager.

  ____________________________________________________________________
  2.0  Installing IPSSEND and IPSMON for OS/2, Windows NT, OR Netware
  ___________________________________________________________________

  To install these programs for OS/2, Windows NT, or NetWare:

  1.  Start the server.

  2.  After the operating system loads, insert the IBM ServeRAID
      Command Line Programs Diskette into the diskette drive.

  3.  If you are using NetWare, go to step 5.  If you are using
      Windows NT or OS/2, create an IPSADM directory on your hard disk
      drive.  To do this, go to the operating system command prompt
      and type:

        md c:\ipsadm

      NOTES:

      a.  The c represents the drive where OS/2 or Windows NT is
          installed.

      b.  If you installed the Administration and Monitoring Program
          files, you already created this directory.

  4.  Press ENTER.

  5.  Copy the IPSSEND.EXE (IPSSEND.NLM if you are using Netware)
      file to your hard disk drive by typing one of the following at
      the command prompt:

      o   For OS/2, type:

            copy a:\os2\ipssend.exe c:\ipsadm

      o   For Windows NT, type:

            copy a:\nt\ipssend.exe c:\ipsadm

      o   For NetWare, type:

            copy a:\netware\ipssend.nlm c:\nwserver

          NOTES:

          a.  The a represents the drive assignment for the diskette
              drive that contains the ServeRAID diskette.

          b.  The c represents the drive where OS/2, Windows NT, or
              NetWare is installed.

          c.  These instructions assume that you installed NetWare in
              the NWSERVER directory.

  6.  Press ENTER; then, copy the IPSMON.EXE file to your hard disk
      drive by typing one of the following at the command prompt:

      o   For OS/2, type:
            copy a:\os2\ipsmon.exe c:\ipsadm

      o   For Windows NT, type:
            copy a:\nt\ipsmon.exe c:\ipsadm

      o   For NetWare, type:
            copy a:\netware\ipsmon.nlm c:\nwserver

          NOTES:

          a.  The a represents the drive assignment for the diskette
              drive that contains the ServeRAID diskette.

          b.  The c represents the drive where OS/2, Windows NT, or
              NetWare is installed.

          c.  These instructions assume that you installed NetWare in
              the NWSERVER directory.

  7.  Press ENTER; then, refer to section 3.0 for information to start
      and use the IPSSEND and IPSMON programs.


  2.20   Installing IPSSEND and IPSMON for OpenServer
  ---------------------------------------------------

  To install these programs for OpenServer 5.0.X:

  1.  Insert the IBM ServeRAID Command Line Programs Diskette into
      the diskette drive.

  2.  Copy the program files from the IBM ServeRAID Command Line
      Programs Diskette by typing the following:

        doscp -r a:/openserv/ipssend /usr/bin/ipssend

  3.  Press ENTER; then, type:

        doscp -r a:/openserv/ipsmon /usr/bin/ipsmon

  4.  Press ENTER; then, change the access permissions by typing
      the following:

        chmod 700 /usr/bin/ipssend

  5.  Press ENTER; then, type:

        chmod 700 /usr/bin/ipsmon

  6.  Press ENTER; then, refer to section 3.0 for information to
      start and use the IPSSEND and IPSMON programs.


  2.30   Installing IPSSEND and IPSMON for Unixware
  -------------------------------------------------

  To install these programs for SCO UnixWare 7.0:

  1.  Insert the IBM ServeRAID Command Line Programs Diskette into
      the diskette drive.

  2.  Mount the diskette by typing the following at the console:

        mount -f dosfs /dev/fd0135ds18/Disk_A

      Note:  If you have more than one diskette drive, you may need to
             replace '/dev/fd0135ds18' with the specific name of the
             diskette drive that you want to use.

             If you currently have something mounted on /Disk_A, you
             will need to create a new directory and substitute its
             name for /Disk_A in these instructions.

  3.  Press ENTER; then copy the program files from the IBM
      ServeRAID Command Line Programs Diskette by typing the
      following:

        cp /Disk_A/unixware/ipssend /usr/bin/ipssend

  4.  Press ENTER; then type:

        cp /Disk_A/unixware/ipsmon /usr/bin/ipsmon

  5.  Press ENTER; then, change the access permissions by typing
      the following:

        chmod 700 /usr/bin/ipssend

  6.  Press ENTER; then, type:

        chmod 700 /usr/bin/ipsmon

  7.  Press ENTER; then, refer to section 3.0 for information to
      start and use the IPSSEND and IPSMON programs.


  ____________________________________________________________________
  3.0  Instructions for Starting and Using IPSSEND and IPSMON
  ___________________________________________________________

  This section provides the information needed to start and use
  the IPSSEND and IPSMON programs.


  3.10  Starting the IPSSEND Program
  ------------------------------------------

  You run the IPSSEND program from the operating system command
  line.

  To start the IPSSEND program:

  o   If you are using OS/2 or Windows NT:

      1.  Type:

          c:\ipsadm\ipssend

      2.  Press ENTER.

          NOTE:  The c represents the drive where OS/2 or Windows NT
                 is installed.

  o   If you are using NetWare:

      1.  From the console, type:

            load c:\nwserver\ipssend

      2.  Press ENTER.

  o   If you are using DOS:

      1.  Insert the bootable IPSSEND diskette into diskette
          drive A; then, type:

            a:\ipssend

      2.  Press ENTER.

  o   If you are using OpenServer or UnixWare:

      1.  Type:

            /usr/bin/ipssend

      2.  Press ENTER.


  3.20  Using the IPSSEND Program
  ---------------------------------------

  When you run the IPSSEND program with no command-line parameters, a
  list of available functions and their specific parameters are
  provided.  All functions require a minimum set of parameters to
  execute the command.  If you run the IPSSEND program with a
  specific function but without its required parameters, specific help
  for that function will appear on the monitor.


  3.30  Starting the IPSMON Program
  ------------------------------------------
  You can run the IPSMON program from the operating system command
  line.

  To start the IPSMON program:

  o   If you are using OS/2 or Windows NT:

      1.  Type:

          c:\ipsadm\ipsmon

      2.  Press ENTER.

          NOTE:  The c represents the drive where OS/2 or Windows NT
                 is installed.

  o   If you are using Novell NetWare:

      1.  From the console, type:

            load c:\nwserver\ipsmon

      2.  Press ENTER.

  o   If you are using SCO OpenServer or UnixWare:

      1.  Type:

            /usr/bin/ipsmon

      2.  Press ENTER.


  3.40  Using the IPSMON Program
  --------------------------------------

  When you start this monitoring program, it immediately begins
  polling all ServeRAID adapters and controllers for specific
  conditions.  If a condition being monitored is found, this program
  logs a message to the monitor, to a file, or to both the monitor and
  a file.

  The IPSMON program uses command-line parameters to determine where
  to log the messages.  If you need help, you can type the "IPSMON -?"
  command for a list of valid parameters.

  If you start this program without any command-line parameters, the
  IPSMON program will log the messages to the IPSMON.LOG file, and the
  messages will not appear on the monitor.

  The valid parameters for IPSMON are:

  o   -F:FILENAME

      Use the -f parameter to specify the name of the file in which to
      record messages.  The default file name is IPSMON.LOG.

  o   -S

      Use the -s parameter to display messages on the standard output
      (usually the monitor).

  o   -?

      Use the -?  parameter to obtain a current list of valid
      parameters.

  After you start the IPSMON program, the program will continuously
  poll the ServeRAID adapters and controllers until you take one of
  the following actions:

  o   If you are using Windows NT or OS/2, press CTRL+C to stop the
      program.

  o   If you are using NetWare, type: "unload c:\nwserver\ipsmon" at
      the system console to stop the program.

  o   If you are using OpenServer or UnixWare, press the DEL key to
      stop the program.


  During operation, the program will log various messages.  Each
  message will contain an alert code and a location specifier.

  o   The alert code begins with the message type and number.  For
      example, INF, WRN, or CRT, followed by the message number.

  o   After the alert code comes the location specifier:

          A specifies the adapter or controller number

          SID specifies the SCSI ID (if required)

          C specifies the channel number (if required)

      For example, a message of CRTxxx:A2C3SID04 signifies that a
      Critical condition (CRTxxx) was found on Adapter 2 (A2), Channel
      3 (C3), SCSI ID 4 (SID04).

      The IPSMON program can log the following messages, based on the
      required condition.

  INFORMATION MESSAGES:
    <Date and Time>  INF000:A1C-SID-- no errors detected
    <Date and Time>  INF001:A1C-SID-- rebuild started
    <Date and Time>  INF002:A1C-SID-- rebuild completed
    <Date and Time>  INF003:A1C-SID-- synchronization started
    <Date and Time>  INF004:A1C-SID-- synchronization completed
    <Date and Time>  INF005:A1C-SID-- migration started
    <Date and Time>  INF006:A1C-SID-- migration completed
    <Date and Time>  INF005:A1C-SID-- FlashCopy started
    <Date and Time>  INF006:A1C-SID-- FlashCopy completed

  WARNING MESSAGES:
    <Date and Time>  WRN001:A2C3SID12 PFA Error detected

  CRITICAL MESSAGES:
    <Date and Time>  CRT001:A3C2SID04  dead drive detected
    <Date and Time>  CRT002:A1C-SID--  not responding to commands
      o  -f:filename
      o  -s

  Use the -f parameter to specify the name of the file to record
  messages.  The default filename is IPSMON.LOG.

  Use the -s parameter to display messages on the standard output
  (usually the monitor).

  ___________________________________________________________________
  5.0  Trademarks and Notices
  ___________________________

   The following terms are trademarks of the IBM Corporation in the
   United States or other countries or both:

   IBM      Netfinity   OS/2     ServeRAID


   Microsoft, Windows, and Windows NT are trademarks or registered
   trademarks of Microsoft Corporation.

   Other company, product, and service names may be trademarks
   or service marks of others.

      THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND.
      IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED,
      INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS
      FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE
      INFORMATION IN THIS DOCUMENT.  BY FURNISHING THIS DOCUMENT, IBM
      GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS.

      Note to U.S.  Government Users -- Documentation related to
      restricted rights -- Use, duplication or disclosure is subject
      to restrictions set forth in GSA ADP Schedule Contract with IBM
      Corp.