1 3 0 4    MICROPOLIS
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 5.25"/FH              Cylinders     830|     |     |
Capacity form/unform    42/      MB        Heads           6|     |     |
Seek time   / track  30.0/ 6.0 ms          Sector/track   17|     |     |
Controller           MFM / ST412           Precompensation 65535
Cache/Buffer               KB              Landing Zone      829
Data transfer rate    0.625 MB/S int       Bytes/Sector      512
                      0.625 MB/S ext
Recording method     MFM                            operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C                 |
Power: sleep              W     Humidity     %                 |
       standby            W     Altitude    km                 |
       idle               W     Shock        g                 |
       seek               W     Rotation   RPM      3600
       read/write         W     Acoustic   dBA
       spin-up            W     ECC        Bit
                                MTBF         h      20000
                                Warranty Month
Lift/Lock/Park     YES          Certificates                                  

**********************************************************************
                        L   A   Y   O   U   T
**********************************************************************
MICROPL. 1320 SERIES  PRODUCT DESCRIPTION 101400 REV. B-3

  +---------------------------------------------------------+
  |                                                         |
  |                                      Interface   +--+   |X1 J1
  |  COMPONENT SIDE                      Terminator  |  |RN1|XX
  |                                                  |  |   |XX
  |                                                  +--+   |XX
  |                                                         |XX
  |                                                         |XX
  |                                               W1 +-+    |XX
  |                                               W2 | |    |
  |                                               DS1| |    |X1
  |                                               DS2| |    |XX J2
  |                                               DS3| |    |XX
  |                                               DS4| |    |XX
  |                                                  +-+    |XX
  |                                                         |XX
  |                                                         |
  |                                                         |
  +---------------------------------------------------------+






     +--------------------------------------+
     |       ++J4                           |
     |       ++                             |
     |          ++J5                        |
     |  J3 Power++                          |
     |  XXXXXX1                             |
     |      J2             J1               |
     |  XXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXX  |
     +--------------1--------------------1--+
      Data Transfer    Control Signal



**********************************************************************
                      J   U   M   P   E   R   S
**********************************************************************
MICROPL. 1300 SERIES  JUMPER SETTING

 Jumper Setting
 ==============

                   J1                  J2       Power
  +----+ +------------------+   +------------+ +--------+
  |    | |1                 |   |1           | | X X    |
  |    +-+                  +---+            +-+W7 W8   |
  |                  W2 Drive Select                    |
  |   xxxxxxxxxx   X X X X X X                          |
  |   RN1         W1   1 2 3 4                          |
  |                                                     |
  |                                                     |
  |                 (COMPONENT SIDE)                    |


 Drive Select Jumpers
 --------------------
 Only one Drive Select jumper is installed on a drive. For every
 drive in a PC/AT installation, move the jumper from DS1 to DS2 (the
 special twisted interface cable that is generally used, takes care of
 assigning a unique address to each drive). Some other systems may
 require that each drive be jumpered to a unique address.

 The drives are shipped with the jumper installed at DS1.

    +------+---------------------------+
    |      |           Pins            |
    |Drive | 1    |2     |3     |4     |
    +------+------+------+------+------+
    |  1   |CLOSED|OPEN  |OPEN  |OPEN  |
    +------+------+------+------+------+
    |  2   |OPEN  |CLOSED|OPEN  |OPEN  |
    +------+------+------+------+------+
    |  3   |OPEN  |OPEN  |CLOSED|OPEN  |
    +------+------+------+------+------+
    |  4   |OPEN  |OPEN  |OPEN  |CLOSED|
    +------+------+------+------+------+


 W1 Write Fault Latch
 --------------------
 W1 is the Write Fault Latch. If W1 is present and the drive
 encounters a write fault, all writing to the drive is inhibited
 until after the drive has been deselected. If W1 is absent, fault
 conditions are not latched. Drives are shipped with a jumper
 installed at W1; remove it for PC/AT installations.


 W2 and W8 are always installed.

 W7 Never install.


 RN1 Interface Terminator
 ------------------------
 The Interface Terminator factory installed at RN1 provides proper
 termination for the interface lines. When daisy-chaining multiple
 1300 drives, leave the terminator in the last physical drive on
 the daisy chain cable; remove the terminator from each of the
 other drives. In most PC/AT installations, the C: drive is actually
 at the end of the cable and should retain the terminator.



**********************************************************************
                      I   N   S   T   A   L   L
**********************************************************************
-ANY DIREC.

 Notes on installation
 =====================

 Installation direction
 ----------------------

     horizontally                           vertically
   +-----------------+             +--+                       +--+
   |                 |             |  +-----+           +-----+  |
   |                 |             |  |     |           |     |  |
 +-+-----------------+-+           |  |     |           |     |  |
 +---------------------+           |  |     |           |     |  |
                                   |  |     |           |     |  |
                                   |  |     |           |     |  |
 +---------------------+           |  +-----+           +-----+  |
 +-+-----------------+-+           +--+                       +--+
   |                 |
   |                 |
   +-----------------+

 The drive will operate in all axis (6 directions).



**********************************************************************
                      F   E   A   T   U   R   E  S
**********************************************************************
MICROPL. 1300 SERIES  PRODUCT DESCRIPTION

 PC Drive Types
 --------------
 Examine the entries in your drive table and find the type that most
 resembles the head and cylinder parameters of the drive without
 exceeding the drive parameters. If you are using third-party
 installation/partitioning software, follow the instructions included
 with the software as it may perform this step automatically.


 Performance Specifications
 --------------------------
 Seek Time (including settling time)     Track-to-Track   6 msec
                                         Average         30 msec
                                         Maximum         60 msec

 Average Rotational Latency                            8.33 msec
 Rotational Speed                              3600 rpm +/- 0.5%
 Data Transfer Rate                                  5 Mbits/sec
 Optimum Step Rate             20 usec or faster (buffered seek)
 MTBF                                               20,000 hours
 Positioner                     Fully balanced rotary voice coil
 Parking                                 Automatic park and lock


 General Functional Specifications
 ---------------------------------
 Encoding Method:  MFM (Modified Frequency Modulation)
 (Although these drives may be capable of functioning in an RLL
 environment, Micropolis does not certify or warrant them for this
 application.)

 Sectoring                                                  Soft
 Write Precompensation Start Cylinder                       830*
 Reduced Write Current Start Cylinder                       830*
 Landing Zone                                                830
 Type of Media                                            Plated
 Mounting Plane                                  Any orientation

 * These are effectively turned off by specifying a non-existent
 cylinder. Some systems accomplish this by using a value of "-1"