4 1 1 0   S    MICROPOLIS
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 3.5"/SLIMLINE         Cylinders    2415|     |     |
Capacity form/unform  1052/ 1205 MB        Heads           9|     |     |
Seek time   / track   8.5/ 1.5 ms          Sector/track     |     |     |
Controller           SCSI2 SI/FAST         Precompensation
Cache/Buffer           512 KB READ-AHEAD   Landing Zone
Data transfer rate    4.000 MB/S int       Bytes/Sector      512
                     10.000 MB/S ext SYNC
Recording method     RLL                            operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C           55    |    -40 75
Power: sleep              W     Humidity     %         5 95    |      5 95
       standby            W     Altitude    km    -0.061  3.048| -0.305 15.240
       idle           7.0 W     Shock        g        10       |     60
       seek           8.5 W     Rotation   RPM      5400
       read/write         W     Acoustic   dBA        32
       spin-up            W     ECC        Bit   126,REED SOLOMON
                                MTBF         h     500000
                                Warranty Month        60
Lift/Lock/Park     YES          Certificates


**********************************************************************
                        L   A   Y   O   U   T
**********************************************************************
MICROPL. 4110  PRODUCT DESCRIPTION 136161 REV. A, NOV. 1993

  +---------------------------------------------------------+
  |+--+W10 Slave Sync Term.                               ++|XX
  |+--+W11 Master Sync Term.                            RN1||XX
  |                             SCSI                      |||XX
  +--1                          ID2+--+                   |||XX
  |  |Option                    ID1|  |    W1-Termination |||XX
  |  |Jumper                    ID0+--+     +-+Power      |||XX
  |  |Block                                               ++|XX
  |  |                                                    ++|XX
  +--+                                                  RN2||XX
 ++ LED                                                   |||XX
 ++                                                       |||XX
  |                                                       |||XX
  |                                                       |||XX
  |                                                       ++|XX1 J1
  |                                                         |
  |                                                         |XX
  |                                                         |XX1 J1A
  +---------------------------------------------------------+



**********************************************************************
                      J   U   M   P   E   R   S
**********************************************************************
MICROPL. 4110  PRODUCT DESCRIPTION 136161 REV. A, NOV. 1993

 Jumper Setting
 ==============

 x = Factory default


 Option Jumper Block
 -------------------

                -   23 21 19 17 15 13 11 9  7  5  3  1
                  +------------------------------------+
         ---------+ o  o  o  o  o  o  o  o  o  o  o  o +----
       ----+-+----+ o  o  o  o  o  o  o  o  o  o  o  o +---
        LED+-+    +------------------------------------+
                +   24 22 20 18 16 14 12 10 8  6  4  2
  Remote LED -------+  |  |  |     |  |  |  |     |  |
  SCSI ID0 ------------+  |  |     |  |  |  |     |  |
  SCSI ID1 ---------------+  |     |  |  |  |     |  |
  SCSI ID2 ------------------+     |  |  |  |     |  |
  SP0 -----------------------------+  |  |  |     |  |
  SP1 --------------------------------+  |  |     |  |
  WP ------------------------------------+  |     |  |
  PTY --------------------------------------+     |  |
  MSYNC ------------------------------------------+  |
  SSYNC ---------------------------------------------+



 Single-Ended Configuration Options
 ----------------------------------

 SCSI ID
 -------
 NOTE:
 There are two identical groups of address jumpers on the Device
 Electronics board; use either group for address selection but not
 both at the same time.

   +----------+-----------------------+ Up to eight devices (the host
   | SCSI ID  |        Jumpers        | and seven targets) can be
   |          | ID2   | ID1   | ID0   | attached to the SCSI Bus.
   +----------+-------+-------+-------+
   |    0     | OPEN  | OPEN  | OPEN  | ID jumpers ID0, ID1 and ID2
   |    1     | OPEN  | OPEN  | CLOSED| are used to assign one of
   |    2     | OPEN  | CLOSED| OPEN  | eight SCSI ID bits (0-7) to
   |    3     | OPEN  | CLOSED| CLOSED| the drive.
   |    4     | CLOSED| OPEN  | OPEN  |
   |    5     | CLOSED| OPEN  | CLOSED| In multiple-device systems,
   |    6     | CLOSED| CLOSED| OPEN  | each drive must have its own
   | x  7     | CLOSED| CLOSED| CLOSED| unique ID.
   +----------+-------+-------+-------+


 Remote LED Option
 -----------------
 LED (user supplied) connected to Remote LED => Both LEDs (on
 Device Electronics board and remote location) are enabled.

 Remote LED is not connected (default) => LED on Device Electronics
 board enabled.


 SP0/SP1  Spindle Control Option
 -------------------------------
 SP0 CLOSED
 SP1 OPEN   Spindle motor starts when START UNIT command is received.

 SP0 OPEN   (default)
 SP1 OPEN   Spindle motor starts at power-on.


 SP0/SP1  Spindle Delay Option
 -----------------------------
 SP1 CLOSED
 SP0 OPEN   Spindle start-up is delayed based on SCSI ID (12 seconds
            per ID).

 SP1 OPEN   (default)
 SP0 OPEN   Spindle motor starts at power on.


 WP  Write Protect Option
 ------------------------
 WP CLOSED  Drive is write protected.
 WP OPEN    Drive is not write protected. (default)


 PTY  Bus Parity Check Option
 ----------------------------
 PTY CLOSED  Drive neither generates nor detects parity.
     OPEN    Drive generates parity and has parity detection enabled.
             (default)


 RN1/RN2  Interface Termination
 ------------------------------
 Terminators INSTALLED (default)
             Drive provides termination for the interface lines.

 Terminators OMITTED
             Drive does not provide termination for the interface
             lines.


 W1/W2/W3  Termination Power Jumper
 ----------------------------------
 Termination
 Power W2 -------+
                 v
               +---+
              ++---+-----+
 +5V to Bus-->|| O |  O  |
 W3           ++---+-----+
              ++---+-----+
              || O |  O  |
              ++---+-----+
               +---+  ^
                      |
 Termination Power W1 +


 W1/W2/W3  Bus Termination Power Option
 --------------------------------------
 W1  CLOSED (default)
     Drive provides terminator power to RN1 and RN2.

 W2  CLOSED
     Host system provides terminator power (via J1 pin 26) to RN1 and
     RN2.

 W3  CLOSED
     Drive provides terminatpr power (via J1, pin 26) to the BUS.


 W10/W11  Spindle Sync Termination
 ---------------------------------
 Spindle Sync Termination depends on system configuration; i.e.,
 Master Mode or Master Control Mode.

 W10 and W11 INSTALLED (default)
             Slave Sync (W10) and Master Sync (W11) are terminated.

 W10 and W11 OPEN
             Spindle sync is not terminated.


 Spindle Synchronization
 -----------------------
 The Rotational Position Locking field (MODE SELECT command, Page Code
 04h) is used to specify spindle synchronization operation.

 NOTE
 that SSYNC = slave sync and MSYNC = master sync

 Unsynchronized: If the drive is set to Unsynchronized (RPL = 00b), it
 ignores the SSYNC signal.

 Slave: If the drive is set to Slave (RPL = 01b), it does not generate
 the MSYNC signal or the SSYNC signal but synchronizes its index to
 the SSYNC signal supplied by an external source.

 Signal termination is placed on the SSYNC signal at the first and the
 last device in the chain only.

 Master: If the drive is set to Master (RPL = 10b), it generates the
 SSYNC output signal for use directly by the slave drives.

 Signal termination is placed on the SSYNC signal at the first and the
 last device in the chain only.

 Master Control: If the drive is set to Master Control (RPL = 11b), it
 generates the MSYNC signal. This output is used by the controller to
 generate the SSYNC signal for the slaves.

 Signal termination is placed on the MSYNC signal at the first and the
 last device in the chain only.

 Signal termination is placed on the SSYNC signal at the first and the
 last device in the chain only.



**********************************************************************
                      I   N   S   T   A   L   L
**********************************************************************
MICROPL. 4110  PRODUCT DESCRIPTION 136161 REV. A, NOV. 1993

 Notes on Installation
 =====================

 Dimensions and Mounting
 -----------------------
 The drives use industry-standard mounting for 3 1/2-inch, 1-inch
 high, Winchester disk drives.


 Drive mounting
 --------------

            horizontally             vertically
         +-----------------+   +--+             +--+
         |                 |   |  +-----+ +-----+  |
         |                 |   |  |     | |     |  |
       +-+-----------------+-+ |  |     | |     |  |
       +---------------------+ |  |     | |     |  |
                               |  |     | |     |  |
                               |  |     | |     |  |
                               |  +-----+ +-----+  |
                               +--+             +--+


 Recommended orientation is vertical on either side, or horizontal
 with the Device Electronics board down; other mounting orientations
 may be used.

 No matter what mounting orientation is used, Micropolis specifies
 that the maximum HDA casting temperature not exceed 60*C (140*F).

 CAUTION
 The mounting screws must be selected so that they do not penetrate
 the bottom mounting holes by more than 0.20 inches or the side
 mounting holes by more than 0.156 inches. Screws that are too long
 may short to PCBA components.

 Mounting Holes: 3 per side, 4 on bottom, 6-32 UNC-2B


 Temperature Measurement
 -----------------------
 Micropolis specifies the maximum HDA casting temperature to be 60*C
 (140*F). Not exceeding this temperature will ensure that head-to-
 media interface never exceeds its temperature limit.

 If the HDA casting temperature measurement cannot be made, the
 ambient air temperature around the drive must be kept at or below
 50*C (122*F).


 J1 Signal Connector
 -------------------
 J1 is 50-pin interface connector. The signals on J1 include the 8-bit
 SCSI bus and various control and handshaking lines.

 Recommended Cable: 3M Scotchflex 3365/50 or equivalent
 Mating connector:  3M P/N 3425-3000 or equivalent


 J1A Power Connector
 -------------------
 J1A is a 4-pin connector used to supply +5V and +12V to the drive.

 Recommended mating connector: AMP 1-480424-0 or equivalent
 Pins: AMP 350078-4
 Suggested wire size: 18 AWG (minimum) for all pins.

  pin 1    +12 VDC
  pin 2    +12 Volts Return
  pin 3    + 5 Volts Return
  pin 4    + 5 VDC


 Spindle Synchronization Connectors (2-pin)
 ------------------------------------------
 Recommended mating connectors: Dupont 69305-002 or equivalent
 Pins: Dupont 77138-001
 Suggested wire size: 26-30 AWG for all pins


 Remote LED Connector (2-pin)
 ----------------------------
 Recommended mating connector: Dupont 69305-002 or equivalent
 Pins: Dupont 77138-001
 Suggested wire size: 26-30 AWG for all pins


 Remote SCSI ID Connector (6-pin)
 --------------------------------
 Recommended mating connector: Dupont 90311-006 or equivalent
 Pins: Dupont 77138-001
 Suggested wire size: 26-30 AWG for all pins


 Remote Option Connector (24-pin)
 --------------------------------
 Recommended mating connector: Dupont 90311-024 or equivalent
 Pins: Dupont 77138-001
 Suggested wire size: 26-30 AWG for all pins


 Interface Electrical Characteristics
 ------------------------------------
 Interface control and status signals are digital (open collector TTL)
 using industry-standard transmitters and receivers which provide
 a terminated, single-ended system.

 For active termination, the assigned signals are terminated with 110
 ohms to +2.85V (nominal). For passive termination, the assigned
 signals are terminated with 220 ohms to +5V (nominal) and 330 ohms to
 ground. All signals use open-collector or tri-state drivers.

 Single-ended drivers and receivers allow a maximum cable length of
 six meters (primarily for connection within a cabinet).

 Signal transmission requires a single 50-conductor (flat or twisted
 pair) cable. A characteristic impedance of 100 ( 10%) ohms is
 recommended.

   a. Input Characteristics

      Each of the drive's signal receivers has the following
      characteristics when measured at the interface connector.

      1) Low-level input voltage (Signal true) = 0.0 VDC to 0.8 VDC

      2) High-level input voltage (Signal false) = 2.0 VDC to 5.25 VDC

      3) Low-level input current = -0.4 milliamps at 0.5 VDC

      4) High-level input current = 0.1 milliamps at 2.7 VDC

      5) Minimum input hysteresis = 0.2 VDC

      6) Maximum input capacitance = 25 pF


   b. Output Characteristics

      Each of the drive's signal drivers has the following
      characteristics when measured at the interface connector.

      1) Low-level input voltage (Signal assertion) = 0.0 VDC to 0.5
                                                      VDC
      2) High-level input voltage (Signal negation) = 2.5 VDC to 5.25
                                                      VDC
      3) Minimum driver output capability = 48 milliamps (sinking) at
                                            0.5 VDC.


   c. Terminator Power (TERMPWR at Pin 26)

      Terminator Power has the following requirements:

      V(TERM) = 4.25 VDC to 5.25 VDC

      800 milliamps minimum source drive capability, with 1.0 amp
      recommended current limiting (e.g., a fuse).

      1.0-milliamp maximum bus loading (except for the purposes of
      providing power to an internal terminator).

 The drive provides keyed connectors to prevent accidental grounding
 or misconnection of terminator power.


 Multiple-Drive Systems
 ----------------------
                                             Drive #1
  +------HOST------+                 +-----------------+
  | +-----------+  +--+-SCSI-BUS-----+ J1              |
  | |Terminators|  |  |       +------+ J1A             |
  | +-----------+  |  |       |      +-----------------+
  |                |  |       |
  +----------------+  |       |              Drive #2
                      |       |      +-----------------+
                      +-------+------+ J1              |
                      |       o------+ J1A             |
                      |       |      +-----------------+
                      |       |
                      |       |              Drive #3
                      |       |      +-----------------+
                      +-------+------+ J1              |
                      |       o------+ J1A             |
                      |       |      +-----------------+
                      |       |
                      |       |              Drive #4
                      |       |      +--------------+--+
                      +-------+------+ J1           |T |
                              o------+ J1A          +--+
           ---DC-VOLTAGES-----+      +-----------------+

 T = TERMINATORS

 Terminators are installed ONLY in the last physical drive in the
 control chain.



**********************************************************************
                      F   E   A   T   U   R   E  S
**********************************************************************
MICROPL. 4110  PRODUCT DESCRIPTION 136161 REV. A, NOV. 1993


 DIFFERENTIAL INTERFACE IS OPTIONAL.

 Some Features of the Drive
 --------------------------
 - Positive media protection is achieved during spin down (due to a
   STOP UNIT command or power off) by automatically retracting and
   locking the positioner in a data-free landing zone.

 - N-Segment Read-Ahead algorithm improves read performance by
   allowing many accesses to be serviced from the 512K cache buffer.

 - Write-Behind Caching, when implemented, provides dramatic
   improvement in write performance by appending multiple write
   commands per disk revolution.

 - In-Line Defect Management (sector slipping) provides maximum
   throughput.

 - Data Integrity is ensured with interface parity through the buffer,
   automatic retries using servo and data strobe offsets, and a 126-
   bit Reed-Solomon ECC on-the-fly.

 - Optional Set Capacity function allows easy matching of block number
   counts for upgrades and emulations.



 Media Defects
 -------------
 Media defects are physical characteristics of the media which result
 in repetitive read errors when a functional drive is operated within
 specified operating conditions.

 At the time of manufacture, a media test system evaluates every
 drive and identifies each media defect location. The defective
 areas are identified by head address (HD), cylinder address (CYL),
 and number of bytes from Index (BFI).

 The list of manufacturer-found defects is stored on the drive in a
 reserved, write-protected area accessible by the SCSI controller.
 This list is known as the MDL (Manufacturers Defect List) or PList
 (Primary Defect List).

 A printed listing of the defects is also shipped with each drive. The
 entries it contains can be mapped out (reassigned) automatically at
 format control parameter bits.


 Seek Time
 ---------

                                          | 4110   |
        ----------------------------------+--------+
        Track-to-Track  read   msec. typ. |   1.5  |
                        write  msec. typ. |   2.5  |
                       Average msec. typ. |   8.5  |
                               msec. max. |  20    |
        Latency                msec. avg. |   5.56 |
        ----------------------------------+--------+


 Recording Media
 ---------------
 Aluminium disks, each 95 millimeters (3 1/2 inches) in diameter, are
 mounted on the spindle assembly. The recording surface on each disk
 is a thin coating of magnetic material, with a carbon over-coat to
 protect it.


 Air Filtration System
 ---------------------
 The drives are designed to provide contamination control within the
 HDA throughout the life of the drive with zero maintenance. Air
 within the HDA is continuously recirculated and filtered through a
 high efficiency filter.

 A breather filter protects the HDA from inward contamination
 migration during air pressure changes associated with drive
 temperature or atmospheric pressure variations.


 Adjustments and Maintenance
 ---------------------------
 The drive requires no adjustments or periodic maintenance;
 additionally, no mechanical adjustments are required to prepare a
 system for handling or shipment.



 MICROPOLIS AV SERIES
 --------------------
 Micropolis AV Series disk drives are engineered specifically for
 multi-media, high-end graphics, and digital video/audio applications.
 With advanced cache management, internal housekeeping improvements,
 and enhanced error handling, AV drives provide the highest minimum
 sustained data rate in their class. AV drives are designed to provide
 a maximum sustained uninterrupted data rate. Unlike data processing
 drives, AV drives guarantee a "worst case" data rate performance.
 This means that with the buffer empty, the maximum access time
 (including error handling) is no more than 30 milliseconds. The
 Micropolis 4110AV drive ensures highly predictable data delivery, so
 you will never miss a frame or a beat.