S T 3 9 1 4 0 W   M E D A L I S T P R O    SEAGATE
                                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 3.5"/SLIMLINE         Cylinders        |     |     |
Capacity form/unform  9100/      MB        Heads           8|     |     |
Seek time   / track  10.0/ 2.5 ms          Sector/track     |     |     |
Controller           ULTRA SCSI/WIDE       Precompensation
Cache/Buffer           512 KB MULTI-SEGMEN Landing Zone
Data transfer rate   20.000 MB/S int       Bytes/Sector      512
                     40.000 MB/S ext SYNC
Recording method     EPRML16/17                     operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C         5 55    |    -40 70
Power: sleep              W     Humidity     %                 |
       standby            W     Altitude    km                 |
       idle               W     Shock        g        10       |    200
       seek          11.0 W     Rotation   RPM      7200
       read/write         W     Acoustic   dBA
       spin-up            W     ECC        Bit   SMART
                                MTBF         h     800000
                                Warranty Month        36
Lift/Lock/Park     YES          Certificates                                  

**********************************************************************
                      J   U   M   P   E   R   S
**********************************************************************
SEAGATE  ST39140/36530/34520N/W/WC  JUMPER SETTING

 Jumper Settings
 ===============

 SCSI ID jumpers
 ----------------
 Each device on the SCSI chain must have a unique SCSI ID.
 The host system's SCSI controller usually uses the ID that has
 the highest priority in the SCSI I/O system. This is always ID7.
 ID0 is lowest priority in an 8-bit I/O system. ID8 is lowest priority
 in a 16-bit I/O system. The lower priority SCSI IDs are normally
 used for other SCSI devices such as this Medalist disc drive.
 Note. Most SCSI controllers (host adapters) allow you to skip a
 SCSI ID. For example, you can have ID0, ID1, and ID3 (skipping ID2).
 Other controllers do not allow this so be sure to refer to your
 system or controller user s manual for details about its requirements
 for proper SCSI device installation.

 Note. This drive is a SCAM (SCSI Configured Auto Magically)
 compliant drive. If the system into which you are installing this
 drive requires SCAM compliant drives, you do not need to be concerned
 about the drive ID jumper settings, as the system automatically
 assigns your new drive the ID it wants it to have. The system may or
 may not use the existing drive ID jumper settings. Setting the drive
 ID doesn't hurt anything, but is not necessary in a SCAM compliant
 system.

 The Medalist disc drives are factory set with the SCSI ID set at 0.
 To change the SCSI ID, refer to the appropriate drive section for
 your model.

 If, after completing the installation process, the drive's LED does
 not show on/off activity when the host is trying to communicate
 with the drive, a duplicate SCSI ID may be the problem. If this is
 the case, change the ID so that each device on the SCSI chain
 has its own unique ID. Also check your system or controller user's
 manual to ensure that you have not violated its SCSI ID numbering
 recommendations.


 Drive termination
 -----------------
 If you are installing a Medalist drive in a system that has other
 SCSI devices installed, terminate only the end devices on the
 SCSI chain. A SCSI device is any disc drive, scanner, tape backup
 unit, or other piece of hardware connected to your system using the
 SCSI bus.

 Note. Some controllers prefer to remain terminated even if they
 are in the middle of the chain. Also, some controllers treat
 the internal and external chains as separate logical buses. This
 means you may need to terminate both the first and last devices on
 both logical buses to achieve proper termination. If necessary, refer
 to your system or controller documentation to see how this is handled
 in your particular system.


 Terminator power
 ----------------
 You usually will not need to change this option and can normally
 leave the drive configured as it was shipped from the factory. For
 information about how to change the terminator power option on
 your drive, refer to the appropriate drive-specific section.
 I/O circuits and data path widths W and WC models have a wide
 (16-bit) SCSI data bus rather than the standard (non-wide) 8-bit SCSI
 data bus; however, you can use these wide drives on a standard
 (non-wide) 8-bit data bus using a terminated 68-pin to 50-pin SCSI
 cable.

 For devices having differential I/O circuits, a maximum cable
 length of 25 meters (82 feet) is allowed. A maximum of 8 devices
 can be connected on an 8-bit wide data bus, and a maximum of 16
 devices can be connected on a 16-bit wide data bus.

 N drives
 ---------
 Terminating the drive
 N model drives are terminated with permanently mounted IC active
 terminators. If you install one of these drives and it is not
 on the end of the SCSI bus, disable the terminators by removing
 the jumper TE from pins 15 and 16 of connector J2. If you install
 the drive on the end of the SCSI bus, enable termination by
 installing a jumper on pins 15 and 16 of connector J2.


 Terminator power
 ----------------
 There are four possible terminator power (TP) configurations for
 N model drives. You will not normally need to change this option and
 can leave the drive configured as it was shipped from the factory.


 W/WD drives section Setting the SCSI ID jumpers
 -----------------------------------------------
 Use the J6 jumper block to set the SCSI ID. To change the SCSI ID,
 install jumpers on the appropriate pins. Optional connections to
 switching circuits in host equipment are provided on J1 auxiliary to
 set the SCSI ID.


 Terminating the drive
 ---------------------
 W model drives are terminated with permanently mounted IC active
 terminators. If you install one of these drives and it is not
 on the end of the SCSI bus, disable the terminators by removing
 the jumper TE from pins 15 and 16 of connector J2. If you install the
 drive on the end of the SCSI bus, enable termination by installing a
 jumper on pins 15 and 16 of connector J2.

 Note. Use active (ANSI SCSI-2 Alternative 2) terminators when
 terminating the bus.


 Terminator power
 ----------------
 There are four possible terminator power (TP) configurations for
 W model drives. You will not normally need to change this option and
 can leave the drive configured as it was shipped from the factory.


 WC drives
 ----------
 WC/DC drives section Setting the SCSI ID jumpers
 The SCSI ID for WC model drives is normally set over the SCSI
 bus by the host system using connector contacts 39 (ID0), 40
 (ID2), 79 (ID1), and 80 (ID3). Users need not install jumpers to
 select SCSI ID.


 Terminating the drive
 ---------------------
 WC model drives do not have internal terminators or any other
 way of adding internal termination to the drive. External
 termination for these drives is normally supplied by the host
 equipment when termination is required.


 SCSI ID - W Models
 ------------------
   +----------+-------------------------------+
   | SCSI ID  |       Jumper Location         |
   |          |  ID8    ID4      ID2     ID1  |
   +----------+-------+-------+-------+-------+
   |    0     | OPEN  | OPEN  | OPEN  | OPEN  |
   +----------+-------+-------+-------+-------+
   |    1     | OPEN  | OPEN  | OPEN  | CLOSED|
   +----------+-------+-------+-------+-------+
   |    2     | OPEN  | OPEN  | CLOSED| OPEN  |
   +----------+-------+-------+-------+-------+
   |    3     | OPEN  | OPEN  | CLOSED| CLOSED|
   +----------+-------+-------+-------+-------+
   |    4     | OPEN  | CLOSED| OPEN  | OPEN  |
   +----------+-------+-------+-------+-------+
   |    5     | OPEN  | CLOSED| OPEN  | CLOSED|
   +----------+-------+-------+-------+-------+
   |    6     | OPEN  | CLOSED| CLOSED| OPEN  |
   +----------+-------+-------+-------+-------+
   |    7     | OPEN  | CLOSED| CLOSED| CLOSED|
   +----------+-------+-------+-------+-------+
   |    8     | CLOSED| OPEN  | OPEN  | OPEN  |
   +----------+-------+-------+-------+-------+
   |    9     | CLOSED| OPEN  | OPEN  | CLOSED|
   +----------+-------+-------+-------+-------+
   |   10     | CLOSED| OPEN  | CLOSED| OPEN  |
   +----------+-------+-------+-------+-------+
   |   11     | CLOSED| OPEN  | CLOSED| CLOSED|
   +----------+-------+-------+-------+-------+
   |   12     | CLOSED| CLOSED| OPEN  | OPEN  |
   +----------+-------+-------+-------+-------+
   |   13     | CLOSED| CLOSED| OPEN  | CLOSED|
   +----------+-------+-------+-------+-------+
   |   14     | CLOSED| CLOSED| CLOSED| OPEN  |
   +----------+-------+-------+-------+-------+
   |   15     | CLOSED| CLOSED| CLOSED| CLOSED|
   +----------+-------+-------+-------+-------+



 SCSI ID
 -------
   +----------+-----------------------+
   | SCSI ID  |        Jumpers        |
   |          | ID4   | ID2   | ID1   |
   +----------+-------+-------+-------+
   |    0     | OPEN  | OPEN  | OPEN  |
   +----------+-------+-------+-------+
   |    1     | OPEN  | OPEN  | CLOSED|
   +----------+-------+-------+-------+
   |    2     | OPEN  | CLOSED| OPEN  |
   +----------+-------+-------+-------+
   |    3     | OPEN  | CLOSED| CLOSED|
   +----------+-------+-------+-------+
   |    4     | CLOSED| OPEN  | OPEN  |
   +----------+-------+-------+-------+
   |    5     | CLOSED| OPEN  | CLOSED|
   +----------+-------+-------+-------+
   |    6     | CLOSED| CLOSED| OPEN  |
   +----------+-------+-------+-------+
   |    7     | CLOSED| CLOSED| CLOSED|
   +----------+-------+-------+-------+



**********************************************************************
                      I   N   S   T   A   L   L
**********************************************************************
SEAGATE  ST39140N  JUMPER SETTING

 Notes on installation
 =====================

 Installation direction
 ----------------------

     horizontally                           vertically
   +-----------------+             +--+                       +--+
   |                 |             |  +-----+           +-----+  |
   |                 |             |  |     |           |     |  |
 +-+-----------------+-+           |  |     |           |     |  |
 +---------------------+           |  |     |           |     |  |
                                   |  |     |           |     |  |
                                   |  |     |           |     |  |
 +---------------------+           |  +-----+           +-----+  |
 +-+-----------------+-+           +--+                       +--+
   |                 |
   |                 |
   +-----------------+

 The drive will operate in all axis (6 directions).


 Providing adequate cooling
 --------------------------
 The enclosure design must ensure adequate cooling for the drive. The
 maximum ambient temperature is 50*C. The drive's product manual
 (32661-001) describes how to evaluate the air-flow design. The
 evaluation consists of ensuring that the case temperature of certain
 critical components remains within acceptable limits during drive
 operation.

 We recommend orienting the drive or directing the air flow in a
 way that creates the least amount of air-flow resistance while
 providing air flow above the circuit boards and around the head
 and disc assembly (HDA). Also, choose the shortest possible
 path between the air inlet and exit. This minimizes the distance
 traveled by air that is heated by the drive and by other nearby
 heat sources.

 The air-flow patterns can be created by the fans either pushing or
 drawing air. The overall flow pattern can be directed from front to
 back, back to front, or side to side.


 Mounting the drive and connecting cables
 ----------------------------------------
 Do not touch the connector pins or any components on the control
 board without observing static-discharge precautions. Always handle
 the drive by the frame only. The drive may be mounted in any
 orientation (horizontally, vertically, and any combination thereof);
 however, you must ensure that the drive receives adequate air flow
 for cooling.

 1. Mount the drive to the host system's chassis using four 6-32
    UNC screws. Two mounting holes are in each side of the
    drive and there are four mounting holes in the bottom of the
    drive.

    The maximum length that the screws should extend into the chassis
    mounting holes is 0.15 inch (3.81 mm), measured from the outer
    surface of the chassis. Tighten the screws down evenly. Do not
    overtighten or force the screw if it does not seem to screw in
    easily, because this means the threads are not properly aligned.
    In this case, back the screw out and try again.

    Note. Signal ground on the power control board (PCB) and the
    head and disc assembly (HDA) are connected together in this drive
    and you cannot separate them. The equipment in which you have
    mounted the drive is connected directly to the HDA and PCB without
    electrically isolating shock mounts. Maximizing the conductive
    contact area between HDA ground and system ground may reduce
    radiated emissions. If you do not want the system chassis to be
    connected to the HDA/PCB ground, you must provide a nonconductive
    (electrically isolating) method of mounting the drive in the
    host system. This may increase radiated emissions and is the
    system designer's responsibility.



**********************************************************************
                      F   E   A   T   U   R   E  S
**********************************************************************
SEAGATE  ST39140N/W/WC  JUMPER SETTING

 Electrostatic discharge protection
 ----------------------------------
 Caution. Removal of circuit boards by personnel not performing
 depot repair will damage components and may void the warranty.

 All drive electronic assemblies are sensitive to static electricity,
 due to the electrostatically sensitive devices used within the
 drive circuitry. Although some devices such as metal-oxide semi-
 conductors are extremely sensitive, all semiconductors, as well
 as some resistors and capacitors, may be damaged or degraded
 by exposure to static electricity.

 Electrostatic damage to electronic devices may be caused by the
 direct discharge of a charged conductor or by exposure to the
 static fields surrounding charged objects. To avoid damaging drive
 electronic assemblies, observe the following precautions
 when installing or servicing the drive:


 - Ground yourself to the drive whenever the drive electronics
   are or will be exposed. Connect yourself to ground with a wrist
   strap (Seagate part number 12263496). Connection may be
   made to any grounded metal assembly. As a general rule, remember
   that you and the drive electronics must all be grounded to avoid
   potentially damaging static discharges.


 - Turn off the power before removing or installing the DC power
   cable.

 - Do not remove any circuit boards from the drive.

 - Never use an ohmmeter on any circuit boards.

 - When installing the drive on a carrier or tray, discharge the
   carrier or tray prior to inserting it into the system.


 Important safety information and precautions
 --------------------------------------------
 Caution. Use forced-air ventilation when benchtesting the drive to
 ensure proper cooling of drive components. Use proper safety
 techniques for safe, reliable operation of this unit.

 The procedures in this manual and labels on the unit contain
 warnings and cautions that must be carefully read and followed
 to minimize or eliminate the risk of personal injury. The warnings
 point out conditions or practices that may endanger you or oth-ers.
 The cautions point out conditions or practices that may damage
 the unit, possibly making it unsafe for use.

 Always observe the following warnings and precautions:

 - Follow all cautions and warnings in the procedures.

 - Use sound safety practices when operating, installing, or
   removing the unit.

 - Use caution when troubleshooting a unit that has voltages
   present. Turn off power to the unit before removing it.

 - Ensure that the internal temperature of the rack or cabinet
   does not exceed the limits defined for the drive when the drive
   is mounted in an equipment rack or cabinet. When units are
   stacked vertically, pay special attention to the top where
   temperatures are usually highest.

 - Follow the precautions listed above in  Electrostatic discharge
   protection.

 - Do not remove any circuit boards from the drive. Return the
   entire drive for depot repair if any circuit board is defective.
   Removal of circuit boards by personnel not performing depot
   repair will damage components and may void the warranty.

 - Do not remove the head and disc assembly (HDA) from the drive.
   Return the entire drive for depot repair if the HDA is defective.

 - Do not attempt to disassemble the HDA. It is not field repairable.
   If the sealed HDA is opened by personnel not performing depot
   repair, this will damage components and void the warranty.

   As a component, this drive is designed to be installed and
   operated in accordance with UL1950, EN60950, CSA C22.2 950-
   M89, and VDE0805.

 Seagate takes all reasonable steps to ensure that its products
 are certifiable to currently accepted standards. Typical applica-
 tions of these disc drives include customer packaging and subsystem
 design. Safety agencies conditionally certify component assemblies,
 such as the Medalist disc drive, based on their final acceptability
 in the enduse product. The subsystem designers are responsible for
 meeting these conditions of acceptability in obtaining safety-
 regulatory agency compliance in their enduse products and for
 certifying where required by law. A necessary part of meeting safety
 requirements is the provision for overcurrent protection on drive
 SELV supply voltages.

 This unit is a component part and as such is not meant to comply
 with FCC or similar national requirements as a stand-alone
 unit. Engineering radiated emissions test results are available
 through the Seagate Safety Department to assist the subsystem
 designer.


 General description
 -------------------
 Medalist Pro SCSI disc drives are highspeed, randomaccess digital-
 data storage devices. The drive is a component for installation in an
 enclosure designed for the drive. This is often a rack within the
 system or an external enclosure designed to house one or more disc
 drives or other peripheral units. In either case, the disc drive must
 receive adequate cooling and it must be sufficiently grounded and
 shielded from emissions.



 Formatting the drive
 --------------------
 Warning. Formatting a drive erases all user data. Be sure that
 you understand this principle before formatting any hard disc drive.
 It is not necessary to format a drive that previously has been used
 to store data, unless your intention is to erase all user data.
 Note. Seagate is not responsible for lost user data.

 1. Turn on DC power.

 2. Boot the system from a system floppy disc or from a previ-ously
    installed hard disc drive if there is one.

 3. Format the disc drive. Medalist Pro disc drives are designed
    to operate with a variety of operating systems. Please refer
    to your system or SCSI controller manual for information
    about formatting and setting up the drive.