Micropolis 1370 Series Disk Drives
                           SPECIFICATIONS

                                   Drive Model Number
Unformatted Capacity:  1373      1373A    1374     1374A     1375

  Total Mbytes         85.3      106.6    127.9    149.3    170.6
  Disk Platters           3          3        4        4        5
  Read/Write Heads        4          5        6        7        8
  Cylinders            ------------------ 1024 ------------------
  Bytes per track      ---------------- 20,832 ------------------

Formatted Capacity

  Total Mbytes         72.9     91.2     109.4    127.6     145.9
  Bytes per Sector     ------------------- 512 ------------------
  Sectors per Track    -------------------- 36 ------------------

PC Drive Types

  When using SCSI in a PC, the most common method is to run your
  setup program and define No Drives Present. The SCSI Host Adapter
  will automatically self-configure on power-up. To install the
  drive, follow the manufacturer's instructions to use the on-board
  BIOS routine or software that was supplied with the Host Adapter.

Performance Specifications

  Seek Time (including settling time)     Track-to-Track   5 msec
                                          Average         23 msec
                                          Maximum         50 msec
  Average Rotational Latency                            8.33 msec
  Rotational Speed                              3600 rpm +/- 0.5%
  Data Transfer Rate at Interface
    Asynchronous                                   1.6 Mbytes/sec
  MTBF                                               30,000 hours
  Positioner                     Fully balanced rotary voice coil
  Parking                                 Automatic park and lock

General Functional Specifications

  Interface                                                  SCSI
  Supports Common Comman  Set
  Write Precompensation Start Cylinder                       1024
  Reduced Write Current Start Cylinder                       1024
  Landing Zone                                               1024
  Mounting Plane                                  Any orientation

Power Requirements

  +12V +/-5%                                             2.0A avg
                                      (4.25A max during start-up)
  +5V +/-5%                                              2.0A avg
    Power dissipation, typical                           35 Watts

Drive Addressing and Interface Termination

                                        ID2___
                                        ID1__ | __W3
          PIN 1                         ID0_ ||| _W18 or W9
          |                                 |||||
   ____________________________________________________________  
  |      |              J1                ||     J2       |    |
  |      |________________________________||______________|    |
  |W1 W2   ==RN1===   ==RN7==   ==RN8===                       |
  |                                                            |
  |                                                            |
  |                                                            |
  |                                                            |
  |                                                            |
  |                                                            |
  |                                                            |
  |           (Component Side)                                 |
  |                                                            |
  |                                                            |
  |                                                            |

ID0, ID1, ID2 SCSI Address Jumpers
  The SCSI ID (drive address) jumpers are identified as ID0, ID1,
  and ID2. ID selection is binary, as shown in the table below.

   SCSI              Jumpers
  Address        ID2   ID1   ID0
  -------        ---   ---   ---
     0           out   out   out
     1           out   out    in
     2           out    in   out
     3           out    in    in
     4            in   out   out
     5            in   out    in
     6            in    in   out
     7            in    in    in

  For  multiple drive installations, on one Host Adapter,each drive
  must unique address. Drives are configured as SCSI ID 0 at the
  factory.

RN1, RN7, RN8 Interface Terminators
  The Interface Terminators factory installed at RN1, RN7, and RN8
  provide proper termination for the interface lines. When
  daisy-chaining multiple drives, leave the terminators installed
  only in the last physical drive on the daisy chain cable; remove
  all three terminators from each of the other drives. In most
  PC/AT installations, the C: drive is actually at the end of the
  cable and should retain the terminators.

W1, W2 Terminator Option
  W1 and W2 select the source of terminator power (+5V) for the
  interface terminators. If a jumper is installed at W1 and no
  jumper is installed at W2 (the factory default configuration),
  the drive provides terminator power. This configuration is used
  for PC/AT applications. If no jumper is installed at W1 but a
  jumper is installed at W2, terminator power is provided by the
  host computer system via interface connector J1, pin 26.

W3 Spindle Option
  W3 selects the spindle control option. If W3 is installed, the
  drive waits for a Start Spindle command (after power is applied)
  to start the spindle motor. If W3 is not installed (the factory
  default configuration), the drive automatically starts the
  spindle motor at power-on. W3 is not installed for PC/AT
  installations.

W18 Bus Parity Option
  W18 selects the parity check option. If W18 is installed, the
  drive neither generates nor detects parity. If W18 is not
  installed (the factory default configuration), the drive
  generates parity and enables parity detection. W18 is not
  installed most PC/AT applications. Refer to your host adapter's
  requirements to verify if parity is to be disabled.

  Note: W18 is labeled "W9" on some 137x boards.