The Complete Portable Plus
                 Using Commute v1.1 and v2.0
                              

This document is provided as "For your information" and as
is.  Neither The Complete PC nor any of it's employees
assume any responsibility for consequences resulting from
the use of the following information nor can the Complete PC
technical support provide help with this document.  The user
of said information does so at his or her own risk.

This document discusses the operation of Central Point
Commute with the Complete Portable Plus data modem.  The
following information will describe the changes necessary to
Commute's configuration parameters to have it function with
the Complete Portable Plus data modem.

Note that the following information is presented with the
assumption that you are using a mouse.  If you are not using
a mouse, please refer to the Commute manual for keyboard
equivalent commands.

Setting up Commute
To configure Commute for use with the Complete Portable Plus
the modem initialization string must be set to the
following.  Choose Configure.  Then select Modem List.  The
Complete Portable Plus is not on the modem selection menu so
you must choose Other and click OK.  In the initialization
string field enter the following string:

ATE0Q0V0X4&C1S7=30S11=125^M (note all 0's=zeros)

MNP users note:  Use the following string instead of the one
above for higher data throughput:

ATE0Q0V0X4&C1\A3\Q3\N3\V1%C1\J0S7=30S11=125^M  (note all
0's=zeros)

Click OK to save the changes.  Choose Configure then Com
Port  and select the Com port that the Portable Plus modem
is installed on.  Then Configure and Baud Rate and set the
baud rate to the Portable Plus maximum speed of 2400 (9600
for MNP users).  Finally select Configure and Connection
Type and make sure Modem is selected.  Commute is now
configured to operate with the Complete Portable Plus modem.

IMPORTANT!
When installing the resident portions of Commute, PFAXBACK
must not be loaded.  You must unload it before going into
Commute.  The background code for Portable Plus (PFAXBACK)
conflicts with modem operations.
Other Considerations
If problems develop please check the following for possible
problems.  Make sure the Com port setting in Commute matches
the setting on the Portable Plus.  If you receive a failure
in connecting be sure to check the modem with a
communications package to ensure the modem functions
properly.  Be sure to check to see if the modem
initialization string matches the above configuration.  If
problems still occur contact Central Point Software to
ensure your Commute settings are correct.