AST RESEARCH, INC.         TECHNICAL BULLETIN # 1232                6-21-95

=


ASCENTIA 910N HANGS WITH PROPERTY MANAGEMENT SOFTWARE


PROBLEM

The Ascentia 910N system may hang when returning from a command process 
(DOS shell) and other modules in Management Reports, Inc.'s Commercial 
Property Management software. 


CAUSE

An older version of Management Reports Incorporated Commercial Property 
Management software causes the above problem. 
.

SYSTEMS AFFECTED
AST PART NUMBER AND DESCRIPTION

501299-XXX      ASCENTIA 900N 4/50 STN - 10"
501300-XXX      ASCENTIA 900N 4/50 TFT - 9"
501302-XXX      ASCENTIA 900N 4/75 STN - 10"
501304-XXX      ASCENTIA 900N 4/75 TFT - 10"

SOLUTION

Contact MRI, Inc. at 1-800-321-8770  for the latest version of their Master 
Program (version 5.1.3) and Commercial Property Management module (ver. 3.4.3).