AST RESEARCH, INC.         TECHNICAL BULLETIN # 1479                3-26-96

=


	Ascentia 900N/910N, ProStation, and Sanyo Torisan 4X IDE CD-ROM


PROBLEM DESCRIPTION

Ascentia 900N/910N computers, with BIOS versions prior to 3.0, may be 
unable to access Sanyo Torisan 4X CD-ROM, with the default ProStation's 
memory address.


SOLUTION

When the Ascentia 900N/910N computer docks with a ProStation (docking station) 
which has a Sanyo Torisan CD-ROM installed, the docking station memory address 
D0000H needs to be changed to C8000H.  To do so, change all switch settings 
on SW1 to the ON position as follows: 
1-ON, 2-ON, 3-ON, and 4-ON.  The setting for SW2 remains the same.

If the Ascentia 910N computer has BIOS version 3.0 (p/n 905580-031) or 
higher installed, the above procedure is not required.  However, if the Sanyo 
Torisan CD-ROM is the only IDE device in the docking station, the CD-ROM needs 
to be set as a Secondary Master, when the CD-ROM driver is installed and the 
CD-ROM jumper is selected.


SYSTEMS AFFECTED
AST Part Number And Description

501589-XXX    All Models
501590-XXX    All Models
501592-XXX    All Models
501299-XXX    4/50 Color 10
501300-XXX    4/50 ColorPlus 9
501302-XXX    4/75 Color 10
501304-XXX    4/75 ColorPlus 10